BM TRADA Q-Mark certified fire door installation
Fire door installation & replacement
SIMETRIA supplies and installs UK-certified, factory-finished fire door sets for PBSA, BTR, hotel and residential buildings, fitted by our own BM TRADA Q-Mark certified installers (STD 052).
From single replacements to whole-building programmes, every door is certified, recorded and backed by our three- and five-year warranty packages.
Discuss Your Installation Project
100
,000
Fire doors manufactured p.a.
4
,
734
Scale - fire doors remediated
225
New fire door sets per lorry
1
Digital Golden Thread
BM TRADA Q-Mark Fire Door Maintenance
Certified inspection, repair and maintenance of fire doors, ensuring continued compliance, performance and safety throughout their service life.
BM TRADA certification
BM TRADA Q-Mark Fire Door Installation
Certified installation of fire door sets to approved standards and manufacturer specifications, ensuring consistent compliance and performance.
BM TRADA certification
BM TRADA Q-Mark Fire Door Compartmentation
Certification of passive fire protection systems, maintaining fire-resisting compartmention and preventing the spread of fire and smoke.
BM TRADA certification
Fire Door Installation & Replacement Services
FIRE DOOR
INSTALLATION & REPLACEMENT
Simetria manages fire door replacement end to end: survey and specification, certified door sets made by our European manufacturing partners, factory-to-site logistics, certified installation and digital handover records for PBSA, BTR, hotel and residential portfolios.
/
01
Survey & specification
We confirm which doors need replacing, then specify fire rating, size, finish, glazing and ironmongery for each opening.



/
02
Certified door sets
UK-certified, pre-hung fire door sets are made by our European manufacturing partners and factory-finished in paint, laminate, veneer or solid wood.



/
03
Logistics
Up to 225 complete door sets per lorry, delivered factory-to-site and sequenced to your installation programme.



/
04
Certified installation
Our own BM TRADA Q-Mark certified installers (STD 052) fit each door set to its tested specification, including frame, seals, closer and ironmongery.



/
05
Handover & records
Each door is certified, labelled and photographed, with installation data added to your digital Golden Thread record.



/
06
Warranty & maintenance
Three- and five-year warranty and service packages keep new doors inspected, maintained and compliant throughout their service life.



Our Process
CERTIFIED FIRE DOOR MANUFACTURING
Our premium certified fire door sets are factory-finished - painted, veneered, laminated or solid wood - and pre hung ready for swift installation.
Discuss Your Project
European
Certified Fire Door Manufacturing
Our European manufacturing partners produce independently EN Standard certified, factory-finished fire door sets, developed in partnership with SIMETRIA, specifically for the UK and European markets.
These are engineered for fast, compliant installation across residential, PBSA, BTR and hotel projects.
Five year service and audit package
UK CERTIFIED FACTORY FINISHED DOOR SETS
PRE-HUNG FIRE DOOR SETS
Factory finish - paint, laminate or veneer
225 COMPLETE FIRE DOOR SETS PER LORRY
Fire door compliance projects
VIEW ALL FIRE COMPLIANCE PROJECTS
Selected fire door and passive fire projects across PBSA, BTR and residential assets covering surveys, remediation, replacement, compartmentation and long-term compliance.
All Fire Door Compliance Projects
want to know more?
Fire Door Compliance Team
We are ready to assist you.
Good afternoon, how can we help with your fire doors compliance?
Chat with us
Fire door installation means fitting a complete, certified fire door set, including the leaf, frame, intumescent and smoke seals, hinges, self-closer and ironmongery, exactly as it was tested.
Installing the full door set to the manufacturer's specification is what makes the door perform in a fire.
Simetria installs under BM TRADA Q-Mark certified procedures for fire door installation (STD 052).
Replacement is recommended when a door has no evidence of its fire rating, has been damaged or altered beyond compliant repair, or when remediation would cost close to a new certified door set.
Simetria follows a remediation-first approach and only recommends replacement where the survey evidence supports it.
Yes. Many defective fire doors can be appropriately remediated rather than replaced, depending on their condition and supporting evidence.
Common repairs include correcting gaps, seals, self-closers, hinges, ironmongery and localised door or frame defects.
Simetria follows a remediation-first approach to reduce unnecessary replacement, cost, waste and disruption. Where a door cannot reasonably or compliantly be remediated, replacement is recommended.
Common defects include doors failing to self-close, damaged or missing intumescent and smoke seals, excessive gaps, defective hinges or closers, unsuitable ironmongery, damaged leaves or frames, inappropriate alterations and damaged glazing.
Simetria records defects at asset level, identifies the required corrective action and maintains evidence of remediation, replacement or further investigation.
BM TRADA Q-Mark is an independent third-party certification scheme providing assurance that certified services are delivered against defined scheme requirements and are independently assessed.
Simetria operates under applicable BM TRADA Q-Mark certified procedures for Fire Door Installation (STD 052), Fire Door Maintenance (STD 058) and Fire Stopping, supporting quality, competence and traceability across our compliance works.
Inspection frequency depends on the building, door type, fire risk assessment and applicable legislation.
In England, multi-occupied residential buildings over 11 metres require communal fire door checks at least every three months and best-endeavours checks of flat entrance doors at least every 12 months.
Simetria provides detailed surveys and structured inspection, maintenance and remediation programmes for individual buildings and multi-site portfolios.
Programme length depends on door numbers, manufacturing lead times and access. Our European manufacturing partners produce factory-finished door sets, and up to 225 complete sets can be delivered per lorry.
Installation is phased around residents and building operations to keep disruption low.
Cost depends on the fire rating, size, finish, glazing, ironmongery and number of doors. Factory-finished, pre-hung door sets reduce on-site labour and finishing time.
Across 10 recent Simetria fire door projects combining remediation and replacement, the total investment came to about £295 to £355 per door. We provide a fixed price after survey.
Fire door records should provide a traceable history of each asset, including identification, location, inspection findings, defects, photographs, remedial works, replacement or installation information and completion evidence.
Simetria maintains digital asset-level records from survey through remediation, installation and ongoing maintenance, creating a clear Golden Thread and audit trail for clients.
The Golden Thread means maintaining accurate, accessible and up-to-date information about a building and its safety-critical assets throughout their lifecycle.
For fire doors, Simetria creates digital asset records showing condition, identified defects, completed works, photographs and supporting evidence, providing continuity from survey through ongoing maintenance and future compliance activity.
Responsibility depends on the building and applicable legislation. Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person has duties for premises covered by the Order, while the Fire Safety Act 2021 clarified its application to flat entrance doors and relevant building elements in multi-occupied residential buildings.
Owners and managing parties should clearly establish responsibility and ensure identified defects are addressed by competent persons.
Fire door requirements sit within a wider legal framework including the Regulatory Reform (Fire Safety) Order 2005, Fire Safety Act 2021, Fire Safety (England) Regulations 2022 and, where relevant, the Building Safety Act 2022 and Building Regulations.
Requirements vary by building type and circumstances, so fire door management should be considered alongside the property's fire risk assessment and current statutory requirements.
We install UK-certified, factory-finished fire door sets made by our European manufacturing partners, available painted, laminated, veneered or in solid wood. Every set is supplied pre-hung with its certification, ready for fast, compliant installation.
Door sets are specified to the fire rating required for each opening.














