BM TRADA Q-Mark certified fire door remediation
Fire door remediation & repairs
SIMETRIA delivers fire door remediation, remedial works and repairs for PBSA, BTR, hotel and residential buildings, bringing existing doors back to compliance under BM TRADA Q-Mark certified procedures.
Our remediation-first approach keeps suitable doors in service, with replacement only where the evidence requires it, planned maintenance and digital asset records for every door.
Discuss Your Remediation Project
100
,000
Fire doors manufactured p.a.
4
,
734
Scale - fire doors remediated
225
New fire door sets per lorry
1
Digital Golden Thread
BM TRADA Q-Mark Fire Door Maintenance
Certified inspection, repair and maintenance of fire doors, ensuring continued compliance, performance and safety throughout their service life.
BM TRADA certification
BM TRADA Q-Mark Fire Door Installation
Certified installation of fire door sets to approved standards and manufacturer specifications, ensuring consistent compliance and performance.
BM TRADA certification
BM TRADA Q-Mark Fire Door Compartmentation
Certification of passive fire protection systems, maintaining fire-resisting compartmention and preventing the spread of fire and smoke.
BM TRADA certification
Fire Door Remediation, Repairs & Maintenance
FIRE DOOR
REMEDIATION & REPAIRS
Simetria turns survey findings into completed, certified remedial works: gaps, seals, closers, hinges and ironmongery corrected, damaged leaves and frames repaired and non-compliant doors replaced, all recorded in one digital Golden Thread across PBSA, BTR, hotel and residential portfolios.
/
01
Survey & scope
We start from a BM TRADA 23-point survey, or validate your existing survey, to confirm defects door by door before any works are priced.



/
02
Remedial works
Gaps, intumescent and smoke seals, self-closers, hinges, latches and ironmongery are corrected using BM TRADA-approved techniques and certified processes.



/
03
Repairs
Damaged door leaves, frames, glazing and inappropriate alterations are repaired wherever the evidence shows the door can compliantly be brought back.



/
04
Replacement where needed
Where a door cannot be remediated, we supply and install UK-certified, factory-finished door sets from our European manufacturing partners.



/
05
Planned maintenance
Scheduled inspection and maintenance programmes keep doors compliant after remediation, so issues are found and fixed before they become failures.



/
06
Golden Thread & warranty
Every completed repair is photographed and recorded at asset level, with three- and five-year warranty and compliance packages available.



Our Process
CERTIFIED FIRE DOOR MANUFACTURING
Our premium certified fire door sets are factory-finished - painted, veneered, laminated or solid wood - and pre hung ready for swift installation.
Discuss Your Project
European
Certified Fire Door Manufacturing
Our European manufacturing partners produce independently EN Standard certified, factory-finished fire door sets, developed in partnership with SIMETRIA, specifically for the UK and European markets.
These are engineered for fast, compliant installation across residential, PBSA, BTR and hotel projects.
Five year service and audit package
UK CERTIFIED FACTORY FINISHED DOOR SETS
PRE-HUNG FIRE DOOR SETS
Factory finish - paint, laminate or veneer
225 COMPLETE FIRE DOOR SETS PER LORRY
Fire door compliance projects
VIEW ALL FIRE COMPLIANCE PROJECTS
Selected fire door and passive fire projects across PBSA, BTR and residential assets covering surveys, remediation, replacement, compartmentation and long-term compliance.
All Fire Door Compliance Projects
want to know more?
Fire Door Compliance Team
We are ready to assist you.
Good afternoon, how can we help with your fire doors compliance?
Chat with us
Fire door remediation is the work needed to bring an existing fire door back to compliance after a survey has found defects.
It typically covers gaps, intumescent and smoke seals, self-closers, hinges, ironmongery, glazing and localised damage to the door leaf or frame.
Simetria carries out remediation under BM TRADA Q-Mark certified procedures for fire door maintenance (STD 058).
Remediation brings a non-compliant door back to the required standard after a survey. Repairs fix specific damage, such as a broken closer or damaged frame. Maintenance is the planned, ongoing work that keeps doors compliant.
Simetria delivers all three as one programme, with a single digital record for each door.
Yes. Many defective fire doors can be appropriately remediated rather than replaced, depending on their condition and supporting evidence.
Common repairs include correcting gaps, seals, self-closers, hinges, ironmongery and localised door or frame defects.
Simetria follows a remediation-first approach to reduce unnecessary replacement, cost, waste and disruption. Where a door cannot reasonably or compliantly be remediated, replacement is recommended.
Common defects include doors failing to self-close, damaged or missing intumescent and smoke seals, excessive gaps, defective hinges or closers, unsuitable ironmongery, damaged leaves or frames, inappropriate alterations and damaged glazing.
Simetria records defects at asset level, identifies the required corrective action and maintains evidence of remediation, replacement or further investigation.
BM TRADA Q-Mark is an independent third-party certification scheme providing assurance that certified services are delivered against defined scheme requirements and are independently assessed.
Simetria operates under applicable BM TRADA Q-Mark certified procedures for Fire Door Installation (STD 052), Fire Door Maintenance (STD 058) and Fire Stopping, supporting quality, competence and traceability across our compliance works.
Inspection frequency depends on the building, door type, fire risk assessment and applicable legislation.
In England, multi-occupied residential buildings over 11 metres require communal fire door checks at least every three months and best-endeavours checks of flat entrance doors at least every 12 months.
Simetria provides detailed surveys and structured inspection, maintenance and remediation programmes for individual buildings and multi-site portfolios.
Programme length depends on door numbers, defects, replacement needs, manufacturing lead times and access. As a guide, recent Simetria projects remediated 319 doors in 6 weeks, 442 doors in 9 weeks and 712 doors in 14 weeks.
Works are phased around residents and building operations to minimise disruption.
Across 10 recent Simetria fire door remediation projects in London and Manchester, the investment came to about £295 to £355 per door, around £316 on average. That covers survey, remediation or replacement, certification and digital records.
The final cost depends on the defects found, the share of doors needing replacement and access. We provide a fixed, costed programme after the survey.
Fire door records should provide a traceable history of each asset, including identification, location, inspection findings, defects, photographs, remedial works, replacement or installation information and completion evidence.
Simetria maintains digital asset-level records from survey through remediation, installation and ongoing maintenance, creating a clear Golden Thread and audit trail for clients.
The Golden Thread means maintaining accurate, accessible and up-to-date information about a building and its safety-critical assets throughout their lifecycle.
For fire doors, Simetria creates digital asset records showing condition, identified defects, completed works, photographs and supporting evidence, providing continuity from survey through ongoing maintenance and future compliance activity.
Responsibility depends on the building and applicable legislation. Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person has duties for premises covered by the Order, while the Fire Safety Act 2021 clarified its application to flat entrance doors and relevant building elements in multi-occupied residential buildings.
Owners and managing parties should clearly establish responsibility and ensure identified defects are addressed by competent persons.
Fire door requirements sit within a wider legal framework including the Regulatory Reform (Fire Safety) Order 2005, Fire Safety Act 2021, Fire Safety (England) Regulations 2022 and, where relevant, the Building Safety Act 2022 and Building Regulations.
Requirements vary by building type and circumstances, so fire door management should be considered alongside the property's fire risk assessment and current statutory requirements.
Yes. Most of our remediation work is delivered in live PBSA, BTR and residential buildings, phased by floor or block and planned around residents and operations.
Fire door works can also be combined with refurbishment and furniture programmes to reduce disruption and contractor interfaces.